MPLAB ICD 4 Help Previous Next


Troubleshooting First Steps : Other Things to Consider : How to Use the Hardware Tool Emergency Boot Firmware Recovery Utility

How to Use the Hardware Tool Emergency Boot Firmware Recovery Utility
WARNING 
Only use this utility to restore hardware tool boot firmware to its factory state.
Use only if your hardware tool no longer functions on any machine.
The debugger may need to be forced into recovery boot mode (reprogrammed) in rare situations; for example, if any of the following occurs when the debugger is connected to the computer:
•
If the debugger has no LEDs lit.
•
If the LEDs are cyan in color.
•
If the procedure described in “How to Invoke the Bootload Mode” was not successful.
You must use MPLAB X IDE v4.15 or greater to use the emergency recovery utility.
Carefully follow the instructions found in MPLAB X IDE under the main menu option Debug>Hardware Tool Emergency Boot Firmware Recovery.
Figure: Selecting Emergency Utility
If the procedure was successful, the recovery wizard displays a success screen. The MPLAB ICD 4 will now be operational and able to communicate with the MPLAB X IDE.
If the procedure failed, try it again. If it fails a second time, contact Microchip Support at
http://support.microchip.com.

Previous Next Microchip Support
Help Updated: 2019-06-25 10:29:53Z